Bellway homes exceed Passivhaus standard at Midhurst

By Published On: September 23rd, 2026Categories: News, Top Stories

Bellway’s first homes built to Passivhaus Standard have achieved an airtightness result of 0.391 air changes per hour (ACH) at its Perceval Grange development in Midhurst, West Sussex.

The result, recorded during final testing on the first four homes, is below the 0.6 ACH@50Pa threshold required for Passivhaus certification.

Bellway is delivering eight two-bedroom Passivhaus homes at the development, with the first four due to be completed and ready for occupation in September.

READ MORE: Taylor Wimpey backs construction mental health outreach with new van

Passivhaus

Construction of the second block of four homes is ongoing.

Bellway achieves 0.391 ACH airtightness result

The first block comprises four terraced homes, which achieved an overall airtightness level of 0.391 ACH at a pressure of 50 Pascals.

For comparison, Bellway said a typical house built by the company has an airtightness level of around 4.5 ACH@50Pa.

The homes have been designed to minimise heat loss and energy use through a combination of airtight construction, thermal insulation and measures to reduce thermal bridging.

Bellway Group Head of Technical and Innovation, Jamie Bursnell, said: “Bellway inherited the planning requirement to construct eight homes to Passivhaus standard on acquiring the land for Perceval Grange, and we have used this as an opportunity to find solutions, upskill our workforce and gain insights into how ultra-airtightness can be delivered at scale.

“With supply chain partner Donaldson Timber Systems, we took a value engineering approach to review and redesign the building fabric with the combined objectives of delivering the U-value required and making the homes as affordable as possible.

READ MORE: Aspire Developments takes ‘Scotland’s Best Building Contractor’ title

“We also worked closely with Aeroseal UK, using their Aeroseal Technology Process to automatically find and fill air gaps in the building fabric, and AES Sustainability, who supported us throughout the certification process from design to final testing.”

Timber frame and MVHR used to reduce heat loss

The homes use pre-insulated timber frame wall panels and an inner air barrier membrane.

Thermal bridging has been reduced through the design of building junctions and the use of external doors and triple-glazed windows with high thermal performance.

Mechanical Ventilation and Heat Recovery (MVHR) systems will recover heat from areas including kitchens and bathrooms and use it to warm living spaces and bedrooms.

The homes will be heated by all-electric air source heat pumps, while solar panels will be installed on the roofs to generate renewable energy.

READ MORE: Falcon Fox begins work on 93-home Sunderland development 

Bursnell added: “The key takeaway from the project is that the two main elements required for airtightness are: simplicity of design to minimise potential gaps in the air barrier; and attention to detail to ensure that no gaps are created or missed.

“We are delighted at the excellent test results that the team on site have achieved here, but more significant is the fact that lessons learned at Perceval Grange will inform the construction of homes by Bellway teams across the UK, as the forthcoming Future Homes Standard building regulations are introduced to reduce carbon emissions generated by the nation’s homes.”

Passivhaus homes include renewable energy features

Additional features at the Perceval Grange homes include rainwater harvesting systems, which will provide water for washing machines and toilet flushing.

Brown roofs are also being installed on the car ports to support biodiversity.

Passivhaus certification focuses on reducing energy demand through measures including high levels of insulation, airtight construction, reduced thermal bridging and efficient ventilation systems.